MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO120
SP-120/240V-20A CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 20 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
METERING HUB CAP
COOPER B-LINE
AWCAP
BASE HUB CAP
METER SOCKET ENTRY; STANDARD OPENING; CIRCLE AW[T], B-LINE[R] BRAND; AW MODEL

Show all:  Meter Socket & Metering Accessories

 Spec Sheet   |   More Details
IN STOCK
TEST BLOCK BYPASS METER SOCKET
COOPER B-LINE
127TB
200A 7T SFTY SKT BOX
RING; SERVICE TYPE OVERHEAD/UNDERGROUND; CIRCUIT CONFIGURATION 3 PHASE 4 WIRE; 600 V; 200 AMPERE; TEST BLOCK BYPASS SWITCH; 7 JAW(S); (1) (1/4-INCH-1/2 INCH) CONCENTRIC KNOCKOUT, (3) (1 1/4 INCH-1-1/2 INCH-2 INCH-2-1/2 INCH) CONCENTRIC KNOCKOUT, (3) (2 INCH-2 1/2 INCH-3 INCH) CONCENTRIC KNOCKOUT KNOCKOUT(S); WIRE SIZE 6 AWG TO 250 KCMIL (LINE/LOAD), 6 TO 1/0 AWG (NEUTRAL); NEMA 3R; SURFACE MOUNTING; SIZE 14 INCH W X 6 INCH D X 30 INCH H; APPROVAL UL 414; CIRCLE AW[T], B-LINE[R] BRAND; APPLICABLE STANDARD ANSI C12.7; FINISH ANSI 61 GRAY ACRYLIC ELECTROCOATED

Show all:  Test Block Bypass Meter Sockets

 More Details
IN STOCK
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO220
2P-120/240V-20A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 20 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CURRENT TRANSFORMER METERING MOUNTING BASE
COOPER B-LINE
6067HA
TFMR MOUNTING BASE
SURFACE; 600 V; 400 AMPERE; CIRCUIT CONFIGURATION 3 PHASE 3/4 WIRE; INTERRUPTING RATING 50 KILOAMPERE; 3 CURRENT TRANSFORMER(S); STUD TERMINAL; USED ON UTILITY/CURRENT TRANSFORMER METER; APPROVAL UL 414; CIRCLE AW[T], B-LINE[R] BRAND; APPLICABLE STANDARD ANSI C12.7

Show all:  Meter Socket & Metering Accessories

 Spec Sheet   |   More Details
IN STOCK
LOAD CENTER GROUND BAR KIT
SQUARE D/TELEMECANIQUE
PK7GTA
GRNDG BAR KIT
CONDUCTOR MATERIAL ALUMINUM/COPPER; 8 TO 1 AWG; USED ON QO[R] LOADCENTER; QO[R] BRAND; PK MODEL

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
IN STOCK
METERING HUB
COOPER B-LINE
AW200
2-IN BASE HUB
2 INCH CONDUIT; SCREW MOUNTING; CIRCLE AW[T], B-LINE[R] BRAND; AW MODEL; APPLICABLE STANDARD ANSI C12.7; HUB WITHOUT GASKET

Show all:  Meter Socket & Metering Accessories

 Spec Sheet   |   More Details
IN STOCK
CURRENT TRANSFORMER METERING
COOPER B-LINE
122013
NEMA3R MTR/TFMR CAB
RING; SERVICE TYPE OVERHEAD/UNDERGROUND; 600 V; 20 AMPERE; 13 JAW(S); H HUB; WIRE SIZE 14 TO 10 AWG (LINE/LOAD/NEUTRAL), 14 TO 2/0 AWG (GROUND); NEMA 3R; SURFACE MOUNTING; SIZE 36 INCH W X 11 INCH D X 42 INCH H; APPROVAL UL 414; CIRCLE AW[T], B-LINE[R] BRAND; APPLICABLE STANDARD ANSI C12.7; FINISH ANSI 61 GRAY ACRYLIC ELECTROCOATED; INCLUDES SNAP TYPE SEALING RING

Show all:  Current Transformer Metering

 More Details
IN STOCK
TEST BLOCK BYPASS METER SOCKET
COOPER B-LINE
117TB
100A 7T SFTY SKT BOX
RING; SERVICE TYPE OVERHEAD/UNDERGROUND; CIRCUIT CONFIGURATION 3 PHASE 4 WIRE; 600 V; 125 AMPERE; TEST BLOCK BYPASS SWITCH; 7 JAW(S); (1) (1/4-INCH-1/2 INCH) CONCENTRIC KNOCKOUT, (5) (1 INCH-1 1/4 INCH-1-1/2 INCH-2 INCH) CONCENTRIC KNOCKOUT, (1) (1 1/4 INCH-1-1/2 INCH-2 INCH-2-1/2 INCH) CONCENTRIC KNOCKOUT KNOCKOUT(S); WIRE SIZE 14 TO 2/0 AWG (LINE/LOAD), 14 TO 1/0 AWG (NEUTRAL); NEMA 3R; SURFACE MOUNTING; SIZE 12 INCH W X 4-5/8 INCH D X 24 INCH H; APPROVAL UL 414; CIRCLE AW[T], B-LINE[R] BRAND; APPLICABLE STANDARD ANSI C12.7; FINISH ANSI 61 GRAY ACRYLIC ELECTROCOATED

Show all:  Test Block Bypass Meter Sockets

 More Details
IN STOCK
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO230
2P-120/240V-30A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 30 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
SAFETY SWITCH
SQUARE D/TELEMECANIQUE
H361RB
30A 600V 3P RT FUS DISC SW
HEAVY DUTY SAFETY; 600 V AC VOLTAGE; 250/600 V DC VOLTAGE; 30 AMPERE CURRENT RATING; POWER RATING 3 HP AT 480 VAC 1 PHASE, 5 HP AT 480 VAC 3 PHASE, 7 1/2 HP AT 600 VAC 3 PHASE (STANDARD); 7 1/2 HP AT 480 VAC 1 PHASE, 15 HP AT 480 VAC 3 PHASE, 20 HP AT 600 VAC 3 PHASE (MAXIMUM); 5 HP AT 250 VDC, 15 HP AT 600 VDC; 3 POLE; 3 WIRE; CLASS R FUSE; FUSIBLE FUSE; SOLID NEUTRAL; NEMA 3R ENCLOSURE; STEEL ENCLOSURE; GALVANIZED FINISH; SIZE 7.55 INCH W X 4.88 INCH D X 14.88 INCH H; APPROVAL UL, CSA; H MODEL; WITH RAIN PROOF BOLT ON HUB

Show all:  Fusible Heavy Duty Safety Switches

 Spec Sheet   |   More Details
IN STOCK
DRY TYPE GENERAL PURPOSE TRANSFORMER
SQUARE D/TELEMECANIQUE
3S1F
3KVA XFMR N3R 480/240-240/120
CONSTRUCTION EPOXY ENCAPSULATED, ENCLOSED, RAIN PROOF, ICE/SLEET PROOF; PRIMARY VOLTAGE 240 X 480 V; SECONDARY VOLTAGE 120/240 V; 60 HZ; POWER RATING 3 KVA; 1 PHASE; TEMPERATURE RISE 115 DEG C; WALL MOUNTING; NEMA 3R ENCLOSURE; SIZE 8.62 INCH W X 6.5 INCH D X 10.5 INCH H; WEIGHT 60 LB; APPLICATION INDOOR/OUTDOOR; APPROVAL UL 506, UL (CANADA AND US), CSA C22.2; APPLICABLE STANDARD NEMA ST-20; ENCLOSURE CODE TYPE 10A; INSULATION TEMPERATURE 180 DEG C; ENCLOSURE MATERIAL PAINTED STEEL

Show all:  General Purpose Dry Type Transformers 600v Or Less

 Spec Sheet   |   More Details
IN STOCK
INDUSTRIAL CONTROL TRANSFORMER
SQUARE D/TELEMECANIQUE
9070TF100D1
100VA 240/480V - 120V FUS TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110/115/120 V; 50/60 HZ; POWER RATING 100 VA; INSULATION CLASS 105; SCREW TERMINAL; TEMPERATURE RISE 55 DEG C; 0.48 INCH L X 0.2 INCH W SLOT MOUNTING; SIZE 3.38 INCH W X 3.34 INCH D X 4.25 INCH H; EN 60742/01.89 APPLICABLE STANDARD; APPROVAL UL, CUL, CSA, CE, NOM; 9070TF MODEL; NUMBER OF PHASE 1; WINDING MATERIAL COPPER; WITH TOP MOUNTED FUSE BLOCK

Show all:  Core & Coil Industrial Control Transformers

 Spec Sheet   |   More Details
IN STOCK
LOAD CENTER AND METER MAIN HUB
SQUARE D/TELEMECANIQUE
B200
2 BOLT-ON HUB
RAIN PROOF; 2 INCH CONDUIT; BOLT ON MOUNTING; USED ON QO[R]/HOMELINE[R] NEMA 3R LOADCENTER; APPROVAL UL

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM120
SP-120/240V-20A CB
COMMON TRIP, THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
* E=Each, C=100, M=1000
First Previous  Page   of  14  Next Last
 
 